SECURITIES AND EXCHANGE COMMISSION
|
Washington, D.C. 20549
|
FORM 8-K
|
Current Report
|
Pursuant to Section 13 or 15(d) of the
|
Securities Exchange Act of 1934
|
Date of Report (Date of earliest event reported): June 7, 2010
|
Commission
File Number
|
Registrant, State of Incorporation,
Address and Telephone Number
|
I.R.S. Employer
Identification
Number
|
||
001-32206
|
GREAT PLAINS ENERGY INCORPORATED
|
43-1916803
|
||
(A Missouri Corporation)
|
||||
1200 Main Street
|
||||
Kansas City, Missouri 64105
|
||||
(816) 556-2200
|
||||
NOT APPLICABLE
|
||||
(Former name or former address,
if changed since last report)
|
||||
000-51873
|
KANSAS CITY POWER & LIGHT COMPANY
|
44-0308720
|
||
(A Missouri Corporation)
|
||||
1200 Main Street
|
||||
Kansas City, Missouri 64105
|
||||
(816) 556-2200
|
||||
NOT APPLICABLE
|
||||
(Former name or former address,
if changed since last report)
|
[ ]
|
Written communications pursuant to Rule 425 under the Securities Act (17 CFR 230.425)
|
[ ]
|
Soliciting material pursuant to Rule 14a-12 under the Exchange Act (17 CFR 240.14a-12)
|
[ ]
|
Pre-commencement communications pursuant to Rule 14d-2(b) under the Exchange Act
|
(17 CFR 240.14d-2(b))
|
|
[ ]
|
Pre-commencement communications pursuant to Rule 13e-4(c) under the Exchange Act (17 CFR 240.13e-4(c))
|
Item 7.01
|
Regulation FD Disclosure
|
Item 9.01
|
Financial Statements and Exhibits
|
(d) Exhibits
|
|
99.1
|
Investor handout (furnished and not deemed filed for the purpose of Section 18 of the Securities Exchange Act of 1934, as amended).
|
GREAT PLAINS ENERGY INCORPORATED
|
|
/s/ Lori A. Wright
|
|
Lori A. Wright
|
|
Vice President and Controller
|
KANSAS CITY POWER & LIGHT COMPANY
|
|
/s/ Lori A. Wright
|
|
Lori A. Wright
|
|
Vice President and Controller
|
Exhibit Index
|
|
Exhibit No.
|
Title
|
99.1
|
Investor handout (furnished and not deemed filed for the purpose of Section 18 of the Securities Exchange Act of 1934, as amended).
|
|
Project description
|
Comments
|
• 100 MW plant in Spearville, KS
• Began construction in 2005
|
ü Completed in Q3 2006
ü In rate base from 1/1/2007
ü No regulatory disallowance
|
|
• Selective Catalytic Reduction (SCR) unit at LaCygne 1
|
ü Completed in Q2 2007
ü In rate base from 1/1/2008
ü No regulatory disallowance
|
|
• Air Quality Control System at Iatan 1
|
ü Completed in Q2 2009
ü In rate base starting 3Q 2009 (KS 08/1 & MO 9/1)
ü No regulatory disallowance in 2009 MO and KS cases;
capped exposure in 2010 cases |
|
• Construction of Iatan 2 super-critical coal plant (850 MW;
73% GXP ownership share)1 |
ü On track for completion Q4 2010
ü Expected in Kansas rates in Q4 2010 / 1Q 2011; Missouri
rates in Q2 2011 |
Rate Case Outcomes
|
||||||
Rate Jurisdiction
|
Amount
Requested |
Amount
Approved |
Effective Date
|
Rate Base
|
Return on Equity
|
Rate-making
Equity Ratio |
KCP&L - Missouri
|
$55.8
|
$50.6
|
1/1/2007
|
$1,270
|
11.25%
|
53.69%
|
KCP&L - Missouri
|
$45.4
|
$35.3
|
1/1/2008
|
$1,298
|
10.75%
|
57.62%
|
KCP&L - Missouri
|
$101.5
|
$95.0
|
9/1/2009
|
$1,4961
|
n/a4
|
46.63%
|
KCP&L - Kansas
|
$42.3
|
$29.0
|
1/1/2007
|
$1,0001
|
n/a2
|
n/a
|
KCP&L - Kansas
|
$47.1
|
$28.0
|
1/1/2008
|
$1,1001
|
n/a3
|
n/a
|
KCP&L - Kansas
|
$71.6
|
$59.0
|
8/1/2009
|
$1,2701
|
n/a4
|
50.75%
|
GMO - MPS
|
$94.5
|
$45.2
|
6/1/2007
|
$918
|
10.25%
|
48.17%
|
GMO - MPS
|
$66.0
|
$48.0
|
9/1/2009
|
$1,1881
|
n/a5
|
45.95%
|
GMO - L&P
|
$24.4
|
$13.6
|
6/1/2007
|
$186
|
10.25%
|
48.17%
|
GMO - L&P
|
$17.1
|
$15.0
|
9/1/2009
|
$2861
|
n/a5
|
45.95%
|